Bacharach Fyrite Pro Combustion Gas Analyzer
$ 176.88
- Description
- Size Guide
Description
Bacharach Fyrite Tech Combustion Gas Analyzer 0024-7268 , TESTED.READY TO USE!
NEW O2 SENSOR
INCLUDING TEMPERATURE PROBE , THERMOMETER ( 0 - 50 F ) WESTON USA,
TUBING, MANUAL , HARD CASE AND 4 X AA BATTERIES
ALASKA , HAWAII AND
PUERTO RICO
EXCLUDED FROM SHIPPING
TECHNICAL CHARACTERISTICS
The Analyzer Directly Measures and Displays:
• Combustion Air (TL) ..............................
........0 to 100
°C (32 to 212 °F)
• Flue Gas O2 content.......................
.................0.0
to 20.9% O2
• Flue Gas Temperature (TA)..........................
.–18 to 537 °C (0
to 999 °F)
• Flue Gas CO content (Model 125E only).............0 to 2,000 ppm CO
• Draft.........................
..............................
.........–9.99
to 67 mb/HPa
(–9.99 to 27 inWC)
The Analyzer Computes and Displays:
(when the measured oxygen level is below 17.9%)
• qA (Stack Loss).........................
......................0 to 99%
• ETa...........................
..............................
.........0
to 109.6%
• Combustion Efficiency....................
................0.1 to 99.9%
• Flue Gas CO Air-Free content (Model 125E only).. 0 to 9,999 ppm
• Flue Gas CO2 content.......................
..............0.1 to a
fuel dependent
maximum value in %
• Excess Air (LAMBDA)......................
.............0 to 9.99
• CO/CO2 (Model 125E only).........................
.........0 to 0.9999
Fuel Selection:
(F1 thru F4 denotes the fuel selected as displayed on the LCD)
• Natural Gas (F1)
• Propane (F2)
• Light Oil (F3)
• City Gas (F4)
Normal Operating Conditions:
Temperature:
• Analyzer ..............................
........................... 0
to 40 °C (32 to 104 °F)
• Probe.........................
..............................
........538
°C max (1,000 °F) at
125 mm insertion
Humidity......................
..............................
........15
to 90% RH,
Accuracy:
• Oxygen........................
.....................
±0.3% O2 with
a typical flue gas
concentration of CO2
• Carbon Monoxide ............................ ±5% of
reading or ±10
ppm, whichever is greater*
• Flue Gas Temperature...................
. ±2 °C between
0 & 124 °C
(±4 °F between 32 & 255 °F)
±3 °C between 125 & 249 °C
(±6 °F between 256 & 480 °F)
±4 °C between 250 & 400 °C
(±8 °F between 481 & 752 °F)
• Second Thermocouple Channel ...... ±2 °C between 0 & 100 °C
(±4 °F between 32 & 212 °F)
• Ambient Temperature...................
.. ±2 °C between 0 & 40 °C
(±4 °F between 32 & 104 °F)