-40%

Bacharach Fyrite Pro Combustion Gas Analyzer

$ 176.88

Availability: 94 in stock
  • Country/Region of Manufacture: United States
  • Bundle Listing: No
  • Return shipping will be paid by: Buyer
  • MPN: 0024-7268
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Modified Item: No
  • Restocking Fee: No
  • Refund will be given as: Money Back
  • Condition: Excellent condition
  • Brand: Bacharach
  • Gas(es) Analyzed: O2, CO, (CO2)

    Description

    Bacharach Fyrite Tech Combustion Gas Analyzer   0024-7268 ,  TESTED.
    READY TO USE!
    NEW O2 SENSOR
    INCLUDING TEMPERATURE PROBE ,  THERMOMETER ( 0 - 50 F )  WESTON  USA,
    TUBING,  MANUAL , HARD CASE  AND 4 X AA   BATTERIES
    ALASKA , HAWAII  AND
    PUERTO RICO
    EXCLUDED FROM SHIPPING
    TECHNICAL CHARACTERISTICS
    The Analyzer Directly Measures and Displays:
    •       Combustion Air (TL) ..............................
    ........0 to 100
    °C (32 to 212 °F)
    •       Flue Gas O2 content.......................
    .................0.0
    to 20.9% O2
    •       Flue Gas Temperature (TA)..........................
    .–18 to 537 °C (0
    to 999 °F)
    •       Flue Gas CO content (Model 125E only).............0 to 2,000 ppm CO
    •       Draft.........................
    ..............................
    .........–9.99
    to 67 mb/HPa
    (–9.99 to 27 inWC)
    The Analyzer Computes and Displays:
    (when the measured oxygen level is below 17.9%)
    •       qA (Stack Loss).........................
    ......................0 to 99%
    •       ETa...........................
    ..............................
    .........0
    to 109.6%
    •       Combustion Efficiency....................
    ................0.1 to 99.9%
    •       Flue Gas CO Air-Free content (Model 125E only).. 0 to 9,999 ppm
    •       Flue Gas CO2 content.......................
    ..............0.1 to a
    fuel dependent
    maximum value in %
    •       Excess Air (LAMBDA)......................
    .............0 to 9.99
    •       CO/CO2 (Model 125E only).........................
    .........0 to 0.9999
    Fuel Selection:
    (F1 thru F4 denotes the fuel selected as displayed on the LCD)
    • Natural Gas (F1)
    • Propane (F2)
    • Light Oil (F3)
    • City Gas (F4)
    Normal Operating Conditions:
    Temperature:
    • Analyzer ..............................
    ........................... 0
    to 40 °C (32 to 104 °F)
    • Probe.........................
    ..............................
    ........538
    °C max (1,000 °F) at
    125 mm insertion
    Humidity......................
    ..............................
    ........15
    to 90% RH,
    Accuracy:
    •      Oxygen........................
    .....................
    ±0.3% O2 with
    a typical flue gas
    concentration of CO2
    •      Carbon Monoxide ............................ ±5% of
    reading or ±10
    ppm, whichever is greater*
    •      Flue Gas Temperature...................
    . ±2 °C between
    0 & 124 °C
    (±4 °F between 32 & 255 °F)
    ±3 °C between 125 & 249 °C
    (±6 °F between 256 & 480 °F)
    ±4 °C between 250 & 400 °C
    (±8 °F between 481 & 752 °F)
    • Second Thermocouple Channel ...... ±2 °C between 0 & 100 °C
    (±4 °F between 32 & 212 °F)
    • Ambient Temperature...................
    .. ±2 °C between 0 & 40 °C
    (±4 °F between 32 & 104 °F)