-40%

Testo 340 Flue Gas Analyzer

$ 2244

Availability: 100 in stock
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money Back
  • MPN: Does Not Apply
  • Condition: Sold As Is. Boots up most of the time, but sometimes hangs. All testing functions work properly. Comes with everything shown, including 1 battery (already inserted into unit).
  • Restocking Fee: No
  • Brand: Testo
  • All returns accepted: Returns Accepted
  • Item must be returned within: 14 Days
  • Country/Region of Manufacture: United States

    Description

    Testo 340 Flue Gas Analyzer
    The Testo 340 is the ideal tool to confirm proper set-up and to identify emission problems before they get serious.  Oxygen is the base sensor in all Testo 340 Analyzers.  Simply add one, or up to three sensors for your specific job.
    This combustion analyzer can be configured in many ways for commissioning commercial boilers, testing engines in midstream gas pipelines, tuning industrial burners in refineries, or cement or glass or any other combustion system that requires high confidence, so you can make the proper control adjustments.
    The back-lit display is easily customized, can display from 4 to 8 lines, or show a variety of measurement options, such as PPM values or as MMBtu/hr. shows measurements
    Important calculation including, combustion efficiency, excess air calculations, corrected NOx and corrected CO values.
    18 fuels to choose from
    On board Diagnostics – Simple Push the I button and scroll down to see instrument status.
    Draft and differential pressure and Mass Emission calculations (i.e. lbs./hr., tons/yr) with any Pitot tube
    Differential Pressure
    Measuring Range
    -80 to 80 InH₂O / -200 to 200 hPa
    Accuracy
    ±0.2 InH₂O (-20.0 to 20.0 InH₂O) / ±0.5 hPa (-49.9 to 49.9 hPa)
    ±1.5 % of mv (Remaining Range)
    Resolution
    0.0 InH₂O / 0.1 hPa
    Absolute Pressure
    Measuring Range
    +240 to +460 InH₂O / +600 to +1150 hPa
    Accuracy
    ±4 InH₂O / ±10 hPa
    Resolution
    1 InH₂O / 1 hPa
    Flue Gas O₂
    Measuring Range
    0 to 25 Vol.%
    Accuracy
    ±0.2 Vol.%
    Resolution
    0.01 Vol.%
    Reaction Time t₉₀
    < 20 sec
    Flue Gas CO
    Measuring Range
    0 to 10000 ppm
    Accuracy
    ±10 ppm or ±10 % of mv (0 to 200 ppm)
    ±20 ppm or ±5 % of mv (201 to 2000 ppm)
    ±10 % of mv (2001 to 10000 ppm)
    Resolution
    1 ppm
    ​Reaction Time t₉₀
    < 40 sec
    Flue Gas COlow
    Measuring Range
    0 to 500 ppm
    Accuracy
    ±2 ppm (0 to 39.9 ppm)
    ±5 % of mv (Remaining Range) data corresponds to 20°C ambient temperature. Additional temperature coefficient 0.25% of reading/K.
    Resolution
    0.1 ppm
    Reaction Time t₉₀
    < 40 sec
    Flue Gas NO
    Measuring Range
    0 to 4000 ppm
    Accuracy
    ±5 ppm (0 to 99 ppm)
    ±5 % of mv (100 to 1999 ppm)
    ±10 % of mv (2000 to 4000 ppm)
    Resolution
    1 ppm
    Reaction Time t₉₀
    < 30 sec
    Flue Gas NOlow
    Measuring Range
    0 to 300 ppm
    Accuracy
    ±2 ppm (0 to 39.9 ppm)
    ±5 % of mv (Remaining Range)
    Resolution
    0.1 ppm
    Reaction Time t₉₀
    < 30 sec
    Flue Gas NO₂
    Measuring Range
    0 to 500 ppm
    Accuracy
    ±10 ppm (0 to 199 ppm)
    ±5 % of mv (Remaining Range)
    Resolution
    0.1 ppm
    Reaction Time t₉₀
    < 40 sec
    To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
    Flue Gas SO₂
    Measuring Range
    0 to 5000 ppm
    Accuracy
    ±10 ppm (0 to 99 ppm)
    ±10 % of mv (Remaining Range)
    Resolution
    1 ppm
    Reaction Time t₉₀
    < 40 sec
    To avoid absorption, a maximum measurement duration of 2 hours should not be exceeded.
    Flue Gas Draft
    Measuring Range
    -16 to +16 InH₂O / -40 to +40 hPa
    Accuracy
    ±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-2.99 to +2.99 hPa)
    ±1.5 % of mv (Remaining Range)
    Resolution
    0.01 InH₂O / 0.01 hPa
    Temperature
    Measuring Range
    -40.0° to 2192.0 °F / -40 to +1200 °C
    Accuracy
    ±0.9 °F (32.0° to 210.2 °F) / ±0.5 °C (0 to +99 °C)
    ±0.5 % of mv (Remaining Range)
    Resolution
    0.1 °F / 0.1 °C
    Efficiency (calculated)
    Measuring Range
    0 to 120 %
    Resolution
    0.1 %
    Flue Gas Loss (calculated)
    ​Measuring Range
    0 to 99.9 %
    Resolution
    0.1 %
    Flue Gas Dewpoint (calculated)
    Measuring Range
    0.0° to 99.9 °Ctd
    Resolution
    0.1 °Ctd
    Flue Gas CO₂ Calculation (calculated from ​O₂)
    ​Measuring Range
    0 to CO₂ max
    Accuracy
    ±0.2 Vol.%
    Resolution
    0.1 Vol.%
    Reaction Time t₉₀
    < 40 sec
    General Technical Data
    Weight
    34 oz. / 960 g
    Dimensions
    11 x 4 x 3 in. / 283 x 103 x 65 mm
    Operating Temperature
    23° to 122 °F / -5 to +50 °C
    Housing
    TPE PC
    Protection Class
    IP40
    Product Colour
    Black
    Connectable Probes
    1 x flue gas probe; 1 x temperature probe; 1 x differential pressure
    Battery Life
    > 6h
    Display Type
    Graphic Display
    Display Size
    160 x 240 pixels
    Power Supply
    Battery block 3.7 V / 2.4 Ah, Mains unit 6.3 V / 2 A
    Maximum Negative Pressure/Flue Gas
    -2.901 psi / -200 mbar
    Maximum Positive Pressure/Flue Gas
    0.725 psi / 50 mbar
    User Defined Fuels
    10 user-defined fuels incl. test gas as fuel
    House Length
    max. 7.8 m (corresponds to two probe hose extensions)
    Pump Flow
    0.6 l/min (regulated)
    Maximum
    100 folders
    Storage per Folder
    Max. 10 sites
    Storage per Site
    Max. 200 logs
    Miscellaneous
    The max. number of logs is determined by the number of folders or sites
    Interface
    Bluetooth®; USB; IR/IRDA interface; gas outlet; Mains connection; probe input/ probe inputs; Differential Pressure
    Storage Temperature
    -4° to 122 °F / -20 to +50 °C