    The TPI Model 716 Flue Gas Analyzer is a state of the art, easy to use analyzer designed not only to display and calculate the required readings from a flue but also to cover most of the other measurements associated with combustion.
    Features
    Using TPI analyzers to determine combustion efficiency at the time of equipment set up minimizes call backs and can be used to verify to the home owner the value of service work by showing the increase in equipment efficiency after work is performed. Efficiency calculation can also be used to generate business by demonstrating the need to improve the efficiency of equipment or to show the benefit of purchasing new equipment with higher efficiency.
    Built-in differential manometer with 0.001” H2O resolution
    Calculates combustion efficiency
    Data Logging with time and date stamp
    Will not shut off if 15 ppm CO is present for increased safety
    Communicate to a PC via the USB interface
    Optional A740 IR printer available for hard copies of test results
    Built-in differential thermometer
    Push on fittings for fast and easy use
    Optional Bluetooth interface
    Applications
    Tuning of residential and furnaces and domestic boilers
    Ambient and stack testing for CO
    CO safety measurements in and around combustion sources
    Temperature checking, including superheat and hydronic differential temperatures
    Dual input differential manometer with 3 selectable units of measure: kPa, mBar, inH20
    Quick And Simple Set Up
    All TPI analyzers feature quick and simple set up. Fast purge and the ability to perform fuel selectionduring start up enable tests to be performed quickly without requiring extra set-up time after initial startup. TPI analyzers also use the last selected fuel as the default setting. This feature prevents the need toperform fuel selection every time the analyzer is turned on.
    The TPI 716 Flue Gas Analyzer comes complete with the following standard accessories:
    TPI 716 Analyzer
    Combustible Gase Leak Probe (A806)
    Rubber Boot (A765) 1 each installed on analyzer
    Soft Carrying Case (A768) - 1 each
    Flue Sampling Probe (A770) - 1 each
    In-Line Filter / Water Trap installed on Flue probe (A795) - 1 each
    Disc water filter installed in water trap (A794W) - 1 each
    Spare In-Line Filter - 1 each (A794F is a package of 5 filters)
    Temperature Probe (GK11M) - 1 each
    Battery Charger (A766) - 1 each
    Mini Pump Protection Filter Assembly (A763) - 1 each
    Exhaust Spigot Removable (A764) - 1 each
    Pressure Tubing (A774) - 1 each 6’ piece
    Static Pressure Tips (A776) - 2 each
    1/4" barbed to 1/8" NPT fitting (A603) - 2 each
    Gas Valve Adapter (A611) - 1 each
    Adapter Tubing (A791) - 1 each 4" piece
    Instruction Manual
    The TPI 716 Flue Gas Analyzer has the following options available:
    A807 PC Software and cable for communication to a PC.
    A740 infrared printer (Included with 716A740)
    New! Optional Bluetooth interface A808
    Model 716 Specifications
    Operating Temperature Range
    14°F to +122°F (-10°C to +50°C)
    Battery / Batery Life
    Rechargeable Ni-MH / > 6 Hours
    Charger Input Voltage
    115V or 230V : 50/60 Hz AC
    Fuels
    Natural Gas, LPG, Light Oil, Heavy Oil, Bituminous Coal,
    Anthracite Coal, Coke, Butane, Wood, Bagasse
    Units of Pressure
    mbar, kPa and inH2O
    Display
    8 line graphical LCD Backlit
    Data Storage
    100 sets of readings
    Data Logging
    400 sets of readings
    Single Logging
    150 sets of readings
    Time and Date
    24 Hour Real Time Clock
    Dimensions
    7.8” x 3.5” x 2.4”
    Weight
    1.1lbs
    Gases
    Range
    Resolution
    Accuracy
    Oxygen
    0-25%
    0.1%
    +/- 0.3%
    Carbon Monoxide
    0-10,000 ppm
    1 ppm
    +/- 5 ppm or 5%
    Carbon Dioxide
    0-25%
    0.1%
    Calculated
    CO/CO2 Ratio
    0-0.999
    0.001
    Calculated
    Combustion Eff.
    0-100%
    Resolution
    Calculated
    Gas Leak Sensor 100-10,000ppm (calibrated to methane)
    Tech Tips
    Several factors affect combustion efficiency.
    Dirty or clogged air filters reduce the amount of air available for combustion therefore reducing efficiency. Obstructions in the flue block exhaust gases and alter the air mixture in the combustion chamber which reduces efficiency. Air leaks in the combustion chamber also alter the mixture causing decreased efficiency.
    The primary way to affect change in combustion efficiency when working with modern gas fired equipment is through gas manifold pressure adjustment.
    Confirm manifold pressures are within manufacturers specifications prior to performing a combustion test. Once manifold pressures are within limits a combustion test can be performed to provide information regarding any adjustments that may be needed.
    10,000ppm is equal to 1%.
    The formula to convert percent to ppm is: ppm = %gas X 10,000. The formula to convert ppm to percent is: % = ppm / 10,000.
    The 709, 712, and 714 incorporate a differential manometer.
    Pressure applied to the (-) port is subtracted from the pressure applied to the (+) port. Examples of pressures being measured:
    (+) port = 10"H2O, (-) port = Not Connected, Displayed reading =10"H2O
    (+) port = 10"H2O, (-) port = 5"H2O, Displayed reading = 5"H2O
    (+) port = Not Connected, (-) port = 10"H2O, Displayed reading = -10"H2O
    Sensor Calibration
    The sensors in your analyzer will need to be replaced periodically and calibration is recommended once every year. Electrochemical sensors by nature are always active. Therefore the time the analyzer is off and not being used must be taken into account when determining sensor life. The sensors in your analyzer are warranted for two years. This warranty does not cover sensors damaged through misuse of the analyzer.
    Frequently Asked Questions
    When should I use the optional A773 oil filter?
    If your analyzer is used in an oil fuel application the A773 filter should be used. This filter does not have to be removed for other fuel types.
    Should I set my analyzer to net or gross efficiency?
    Gross efficiency is the correct choice for applications in the United States.
    Can I use any of the TPI analyzers to test for the presence of combustible gas in the flue?
    Yes, the 712 has the ability to test for combustible gases in the flue.
    Can I log and send test data to a computer?
    Yes, the 712 and 714 have the ability to communicate to a computer by using the optional A767 infrared adapter.
    Can I test for CO in ambient air?
    Yes, the 708, 709, 712, and 714 can all test for carbon monoxide in ambient air.
    Do any of the TPI analyzers have a built in manometer?
    Yes, the 709, 712, and 714 have built in differential manometers.